CX1154L
Abstract: CX1154L thyratron CX1154 ka klystron pulse thyratrons Thyratron thyratron tube operation A1A-CX1154L klystron tubes schematic diagram heater
Text: E2V Technologies CX1154L Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring fast recovery time, low jitter, firing time
|
Original
|
PDF
|
CX1154L
CX1154
CX1154L,
CX1154L
CX1154L thyratron
ka klystron pulse
thyratrons
Thyratron
thyratron tube operation
A1A-CX1154L
klystron tubes
schematic diagram heater
|
CX1151L
Abstract: thyratron thyratron tube operation R2G1 MA360A
Text: E2V Technologies CX1151L Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, fast recovery tetrode thyratron, specifically designed for operation under medical linac conditions, but also
|
Original
|
PDF
|
CX1151L
CX1151L,
CX1151L
thyratron
thyratron tube operation
R2G1
MA360A
|
CX1140L
Abstract: CX1140 CX114 thyratron tube operation A1A-CX1140 MA360 E2V Technologies thyratron tube thyratron A1A-CX1140L
Text: CX1140L Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, fast recovery, tetrode thyratron, specifically designed for operation under medical linac conditions. A reservoir operating from the cathode heater supply is incorporated.
|
Original
|
PDF
|
CX1140L
CX1140L,
CX1140L
CX1140
CX114
thyratron tube operation
A1A-CX1140
MA360
E2V Technologies
thyratron tube
thyratron
A1A-CX1140L
|
CX1551
Abstract: CX1140LD cx1140 thyratron tube operation MA360 thyratron tube 4316A 1bg23 thyratron Thyratron recovery time
Text: CX1140LD Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, fast recovery, tetrode thyratron, specifically designed for operation under medical linac conditions. A reservoir operating from the cathode heater supply is
|
Original
|
PDF
|
CX1140LD
CX1140LD,
CX1551
CX1140LD
cx1140
thyratron tube operation
MA360
thyratron tube
4316A
1bg23
thyratron
Thyratron recovery time
|
Untitled
Abstract: No abstract text available
Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-53 Hydrogen Tetrode Thyratron Description The HY53 is a hydrogen illed tetrode thyratron. The auxiliary grid, G1, allows the user to reduce the total anode delay time and time jitter. Relatively high pulse currents are achievable
|
Original
|
PDF
|
HY-53
HY-53
|
KV 147
Abstract: thyratron tube operation CX1174 thyratron 6890A E2V TECHNOLOGIES BR/BW1617F E2V TECHNOLOGIES BR/BW1617F SERIES thyratron tube schematic diagram heater thyratron diagram
Text: E2V Technologies CX1174 Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for
|
Original
|
PDF
|
CX1174
CX1174,
KV 147
thyratron tube operation
CX1174
thyratron
6890A
E2V TECHNOLOGIES BR/BW1617F
E2V TECHNOLOGIES BR/BW1617F SERIES
thyratron tube
schematic diagram heater
thyratron diagram
|
CX2801
Abstract: CX1574C CX1535 CX1585A CX1140 CX1157 CX1836A cx2804 e2v spark gaps Thyratron dc to ac inverter
Text: E2V Technologies Hydrogen Thyratrons Preamble Table of Contents 1 INTRODUCTION . . . . . . . . . . . . . 2 DESCRIPTION . . . . . . . . . . . . . . 2 2 PRINCIPLES OF OPERATION . . . . . THE SWITCHING CYCLE . . . . . . . i. Voltage Hold-off . . . . . . . . ii. Commutation . . . . . . . . .
|
Original
|
PDF
|
180A-5
CX2801
CX1574C
CX1535
CX1585A
CX1140
CX1157
CX1836A
cx2804
e2v spark gaps
Thyratron dc to ac inverter
|
CX1159
Abstract: CX-1159 Thyratron 1159 thyratron tube Thyratron recovery time
Text: CX-1159 NATIONAL DUETERIUM THYRATRON Tetrode ABRIDGED DATA Deuterium Filled Tetrode Thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition rates, in parallel for switching higher powers, or for switching long pulses. A reservoir operating
|
Original
|
PDF
|
CX-1159
14xl09
CX1159
CX-1159
Thyratron
1159
thyratron tube
Thyratron recovery time
|
jan8613
Abstract: jan-7782 JAN 7322 PerkinElmer spark gap thyratrons JAN 7665A jan 7782 7665A thyratron tube jan 7621 Thyratron
Text: Imaging D A T A S H E E T Lighting Telecom High Energy Switches Thyratrons Description Features Thyratrons are fast acting high voltage switches suitable for a variety of applications including radar, laser and scientific use. • Wide operating voltage range
|
Original
|
PDF
|
DS-247
jan8613
jan-7782
JAN 7322
PerkinElmer spark gap
thyratrons
JAN 7665A
jan 7782
7665A
thyratron tube jan 7621
Thyratron
|
CX1171C
Abstract: Thyratron 7105B 105 Thyratron thyratron tube operation
Text: CX1171C Three-Gap Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. The design of the control grids permits heavy pretriggering, which allows the thyratron to switch high peak
|
Original
|
PDF
|
CX1171C
3573B
CX1171C,
CX1171C
Thyratron
7105B
105 Thyratron
thyratron tube operation
|
CX1151
Abstract: E2V Technologies tag 725 thyratrons thyratron
Text: E2V Technologies CX1151 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition
|
Original
|
PDF
|
CX1151
CX1151,
CX1151
E2V Technologies
tag 725
thyratrons
thyratron
|
CX1140
Abstract: Thyratron 5949 5949A Thyratron 5948 CV8563 CX-1140 CX1151 MA179 MA360 thyratrons
Text: CX1140 Service Type CV8563 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition
|
Original
|
PDF
|
CX1140
CV8563)
CX1140
CX1140,
Thyratron 5949
5949A
Thyratron 5948
CV8563
CX-1140
CX1151
MA179
MA360
thyratrons
|
CX1168
Abstract: thyratron
Text: E2V Technologies CX1168 Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift.
|
Original
|
PDF
|
CX1168
3573B
CX1168,
CX1168
thyratron
|
Thyratron
Abstract: CX1171 thyratron tube operation SPACE HEATER thyratron tube schematic diagram Storage heater schematic diagram crowbar for 12 v dc power supply
Text: E2V Technologies CX1171 Three-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and
|
Original
|
PDF
|
CX1171
CX1171,
Thyratron
CX1171
thyratron tube operation
SPACE HEATER
thyratron tube
schematic diagram Storage heater
schematic diagram crowbar for 12 v dc power supply
|
|
CX1551
Abstract: CX1159 CX-1159 CX155 MA179 MA360 MA92 thyratron tube thyratron BS448
Text: CX1159 Service Type CV9080 Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition
|
Original
|
PDF
|
CX1159
CV9080)
CX1159,
CX1551
CX1159
CX-1159
CX155
MA179
MA360
MA92
thyratron tube
thyratron
BS448
|
Thyratron
Abstract: CX1168 thyratron tube operation thyratron tube
Text: E2V Technologies CX1168C Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift. The
|
Original
|
PDF
|
CX1168C
3573B
CX1168C,
Thyratron
CX1168
thyratron tube operation
thyratron tube
|
thyratron tube operation
Abstract: Thyratron HY-3202
Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-3189 Deuterium Grounded Grid Thyratron Description The HY-3189 is a deuterium-illed, triode thyratron designed for grounded grid operation. The grounded grid coniguration Note 1 allows the tube to be operated at a higher peak
|
Original
|
PDF
|
HY-3189
HY-3189
Rating775
thyratron tube operation
Thyratron HY-3202
|
Untitled
Abstract: No abstract text available
Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-11 Hydrogen Filled Triode Thyratron Description The HY-11 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation at a lower to moderate voltage and very high pulse repetition rates when compared
|
Original
|
PDF
|
HY-11
HY-11
|
thyratron
Abstract: thyratrons thyratron tube operation CX1599 thyratron tube Thyratron recovery time
Text: CX1599 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring extremely low jitter, low anode delay time drift and high rate of rise of current. A hydrogen reservoir operating
|
Original
|
PDF
|
CX1599
CX1599
CX1599,
thyratron
thyratrons
thyratron tube operation
thyratron tube
Thyratron recovery time
|
CX1164
Abstract: E2V Technologies thyratron A1A-CX1164 105 Thyratron
Text: E2V Technologies CX1164 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for
|
Original
|
PDF
|
CX1164
CX1164
CX1164,
E2V Technologies
thyratron
A1A-CX1164
105 Thyratron
|
Untitled
Abstract: No abstract text available
Text: HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron NOTE The HY3002/5948A-REPLACEMENT The HY-3002 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation is a HY3002 that incorporates a base at a moderately-high voltage and very high pulse repetition rates when compared to similar
|
Original
|
PDF
|
HY-3002/5948A-Replacement
HY3002/5948A-REPLACEMENT
HY-3002
HY3002
HY3002/5948AREPLACEMENT
HY-3002/5984A-Replacement
|
Untitled
Abstract: No abstract text available
Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-5 Hydrogen Filled Tetrode Thyratron Description The HY-5 is a hydrogen illed triode thyratron. Relatively high pulse currents are achievable using only free or forced air convection cooling. The tube may be mounted by its cathode
|
Original
|
PDF
|
|
8503B
Abstract: Thyratron 3329B thyratron tube operation thyratron tube thyratrons
Text: E2V Technologies 8503B Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. Environmental tests applied to the tube include linear acceleration at 12 g, and
|
Original
|
PDF
|
8503B
8503B,
8503B
Thyratron
3329B
thyratron tube operation
thyratron tube
thyratrons
|
thyratron 16 H
Abstract: CX1157 CV6241 E2V Technologies cx1157 thyratron 500KV
Text: E2V Technologies CX1157 Service Type CV6241 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. (Absolute values) ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for
|
Original
|
PDF
|
CX1157
CV6241)
CX1157,
thyratron 16 H
CX1157
CV6241
E2V Technologies cx1157
thyratron
500KV
|