Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THYRATRON RECOVERY TIME Search Results

    THYRATRON RECOVERY TIME Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    AM27S25DM Rochester Electronics LLC OTP ROM Visit Rochester Electronics LLC Buy
    AM27C256-55PC Rochester Electronics LLC OTP ROM, Visit Rochester Electronics LLC Buy
    ICM7170AIDG Rochester Electronics LLC Real Time Clock, CMOS, CDIP24, ROHS COMPLIANT, CERAMIC, DIP-24 Visit Rochester Electronics LLC Buy
    ICM7170AIBG Rochester Electronics LLC Real Time Clock, CMOS, PDSO24, ROHS COMPLIANT, PLASTIC, MS-013AD, SOP-24 Visit Rochester Electronics LLC Buy
    ICM7170IBG Rochester Electronics LLC Real Time Clock, CMOS, PDSO24, ROHS COMPLIANT, PLASTIC, MS-013AD, SOP-24 Visit Rochester Electronics LLC Buy

    THYRATRON RECOVERY TIME Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    CX1154L

    Abstract: CX1154L thyratron CX1154 ka klystron pulse thyratrons Thyratron thyratron tube operation A1A-CX1154L klystron tubes schematic diagram heater
    Text: E2V Technologies CX1154L Deuterium Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring fast recovery time, low jitter, firing time


    Original
    PDF CX1154L CX1154 CX1154L, CX1154L CX1154L thyratron ka klystron pulse thyratrons Thyratron thyratron tube operation A1A-CX1154L klystron tubes schematic diagram heater

    CX1151L

    Abstract: thyratron thyratron tube operation R2G1 MA360A
    Text: E2V Technologies CX1151L Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, fast recovery tetrode thyratron, specifically designed for operation under medical linac conditions, but also


    Original
    PDF CX1151L CX1151L, CX1151L thyratron thyratron tube operation R2G1 MA360A

    CX1140L

    Abstract: CX1140 CX114 thyratron tube operation A1A-CX1140 MA360 E2V Technologies thyratron tube thyratron A1A-CX1140L
    Text: CX1140L Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled, fast recovery, tetrode thyratron, specifically designed for operation under medical linac conditions. A reservoir operating from the cathode heater supply is incorporated.


    Original
    PDF CX1140L CX1140L, CX1140L CX1140 CX114 thyratron tube operation A1A-CX1140 MA360 E2V Technologies thyratron tube thyratron A1A-CX1140L

    CX1551

    Abstract: CX1140LD cx1140 thyratron tube operation MA360 thyratron tube 4316A 1bg23 thyratron Thyratron recovery time
    Text: CX1140LD Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, fast recovery, tetrode thyratron, specifically designed for operation under medical linac conditions. A reservoir operating from the cathode heater supply is


    Original
    PDF CX1140LD CX1140LD, CX1551 CX1140LD cx1140 thyratron tube operation MA360 thyratron tube 4316A 1bg23 thyratron Thyratron recovery time

    Untitled

    Abstract: No abstract text available
    Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-53 Hydrogen Tetrode Thyratron Description The HY53 is a hydrogen illed tetrode thyratron. The auxiliary grid, G1, allows the user to reduce the total anode delay time and time jitter. Relatively high pulse currents are achievable


    Original
    PDF HY-53 HY-53

    KV 147

    Abstract: thyratron tube operation CX1174 thyratron 6890A E2V TECHNOLOGIES BR/BW1617F E2V TECHNOLOGIES BR/BW1617F SERIES thyratron tube schematic diagram heater thyratron diagram
    Text: E2V Technologies CX1174 Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. Suitable for


    Original
    PDF CX1174 CX1174, KV 147 thyratron tube operation CX1174 thyratron 6890A E2V TECHNOLOGIES BR/BW1617F E2V TECHNOLOGIES BR/BW1617F SERIES thyratron tube schematic diagram heater thyratron diagram

    CX2801

    Abstract: CX1574C CX1535 CX1585A CX1140 CX1157 CX1836A cx2804 e2v spark gaps Thyratron dc to ac inverter
    Text: E2V Technologies Hydrogen Thyratrons Preamble Table of Contents 1 INTRODUCTION . . . . . . . . . . . . . 2 DESCRIPTION . . . . . . . . . . . . . . 2 2 PRINCIPLES OF OPERATION . . . . . THE SWITCHING CYCLE . . . . . . . i. Voltage Hold-off . . . . . . . . ii. Commutation . . . . . . . . .


    Original
    PDF 180A-5 CX2801 CX1574C CX1535 CX1585A CX1140 CX1157 CX1836A cx2804 e2v spark gaps Thyratron dc to ac inverter

    CX1159

    Abstract: CX-1159 Thyratron 1159 thyratron tube Thyratron recovery time
    Text: CX-1159 NATIONAL DUETERIUM THYRATRON Tetrode ABRIDGED DATA Deuterium Filled Tetrode Thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition rates, in parallel for switching higher powers, or for switching long pulses. A reservoir operating


    Original
    PDF CX-1159 14xl09 CX1159 CX-1159 Thyratron 1159 thyratron tube Thyratron recovery time

    jan8613

    Abstract: jan-7782 JAN 7322 PerkinElmer spark gap thyratrons JAN 7665A jan 7782 7665A thyratron tube jan 7621 Thyratron
    Text: Imaging D A T A S H E E T Lighting Telecom High Energy Switches Thyratrons Description Features Thyratrons are fast acting high voltage switches suitable for a variety of applications including radar, laser and scientific use. • Wide operating voltage range


    Original
    PDF DS-247 jan8613 jan-7782 JAN 7322 PerkinElmer spark gap thyratrons JAN 7665A jan 7782 7665A thyratron tube jan 7621 Thyratron

    CX1171C

    Abstract: Thyratron 7105B 105 Thyratron thyratron tube operation
    Text: CX1171C Three-Gap Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and drift. The design of the control grids permits heavy pretriggering, which allows the thyratron to switch high peak


    Original
    PDF CX1171C 3573B CX1171C, CX1171C Thyratron 7105B 105 Thyratron thyratron tube operation

    CX1151

    Abstract: E2V Technologies tag 725 thyratrons thyratron
    Text: E2V Technologies CX1151 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition


    Original
    PDF CX1151 CX1151, CX1151 E2V Technologies tag 725 thyratrons thyratron

    CX1140

    Abstract: Thyratron 5949 5949A Thyratron 5948 CV8563 CX-1140 CX1151 MA179 MA360 thyratrons
    Text: CX1140 Service Type CV8563 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition


    Original
    PDF CX1140 CV8563) CX1140 CX1140, Thyratron 5949 5949A Thyratron 5948 CV8563 CX-1140 CX1151 MA179 MA360 thyratrons

    CX1168

    Abstract: thyratron
    Text: E2V Technologies CX1168 Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift.


    Original
    PDF CX1168 3573B CX1168, CX1168 thyratron

    Thyratron

    Abstract: CX1171 thyratron tube operation SPACE HEATER thyratron tube schematic diagram Storage heater schematic diagram crowbar for 12 v dc power supply
    Text: E2V Technologies CX1171 Three-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, three-gap, high voltage thyratron with ceramic/metal envelope, featuring low jitter, firing time and


    Original
    PDF CX1171 CX1171, Thyratron CX1171 thyratron tube operation SPACE HEATER thyratron tube schematic diagram Storage heater schematic diagram crowbar for 12 v dc power supply

    CX1551

    Abstract: CX1159 CX-1159 CX155 MA179 MA360 MA92 thyratron tube thyratron BS448
    Text: CX1159 Service Type CV9080 Deuterium Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled tetrode thyratron, featuring low jitter and low anode delay time drift. Suitable for use at high pulse repetition


    Original
    PDF CX1159 CV9080) CX1159, CX1551 CX1159 CX-1159 CX155 MA179 MA360 MA92 thyratron tube thyratron BS448

    Thyratron

    Abstract: CX1168 thyratron tube operation thyratron tube
    Text: E2V Technologies CX1168C Two-Gap Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled, two-gap, high voltage thyratron with ceramic/ metal envelope, featuring low jitter, firing time and drift. The


    Original
    PDF CX1168C 3573B CX1168C, Thyratron CX1168 thyratron tube operation thyratron tube

    thyratron tube operation

    Abstract: Thyratron HY-3202
    Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-3189 Deuterium Grounded Grid Thyratron Description The HY-3189 is a deuterium-illed, triode thyratron designed for grounded grid operation. The grounded grid coniguration Note 1 allows the tube to be operated at a higher peak


    Original
    PDF HY-3189 HY-3189 Rating775 thyratron tube operation Thyratron HY-3202

    Untitled

    Abstract: No abstract text available
    Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-11 Hydrogen Filled Triode Thyratron Description The HY-11 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation at a lower to moderate voltage and very high pulse repetition rates when compared


    Original
    PDF HY-11 HY-11

    thyratron

    Abstract: thyratrons thyratron tube operation CX1599 thyratron tube Thyratron recovery time
    Text: CX1599 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring extremely low jitter, low anode delay time drift and high rate of rise of current. A hydrogen reservoir operating


    Original
    PDF CX1599 CX1599 CX1599, thyratron thyratrons thyratron tube operation thyratron tube Thyratron recovery time

    CX1164

    Abstract: E2V Technologies thyratron A1A-CX1164 105 Thyratron
    Text: E2V Technologies CX1164 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for


    Original
    PDF CX1164 CX1164 CX1164, E2V Technologies thyratron A1A-CX1164 105 Thyratron

    Untitled

    Abstract: No abstract text available
    Text: HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron NOTE The HY3002/5948A-REPLACEMENT The HY-3002 is a hydrogen-illed, triode thyratron. The hydrogen gas ill facilitates reliable operation is a HY3002 that incorporates a base at a moderately-high voltage and very high pulse repetition rates when compared to similar


    Original
    PDF HY-3002/5948A-Replacement HY3002/5948A-REPLACEMENT HY-3002 HY3002 HY3002/5948AREPLACEMENT HY-3002/5984A-Replacement

    Untitled

    Abstract: No abstract text available
    Text: ENGAGE. ENABLE. EXCEL. www.excelitas.com HY-5 Hydrogen Filled Tetrode Thyratron Description The HY-5 is a hydrogen illed triode thyratron. Relatively high pulse currents are achievable using only free or forced air convection cooling. The tube may be mounted by its cathode


    Original
    PDF

    8503B

    Abstract: Thyratron 3329B thyratron tube operation thyratron tube thyratrons
    Text: E2V Technologies 8503B Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled triode thyratron, positive grid, for pulse operation. A hydrogen reservoir is incorporated. Environmental tests applied to the tube include linear acceleration at 12 g, and


    Original
    PDF 8503B 8503B, 8503B Thyratron 3329B thyratron tube operation thyratron tube thyratrons

    thyratron 16 H

    Abstract: CX1157 CV6241 E2V Technologies cx1157 thyratron 500KV
    Text: E2V Technologies CX1157 Service Type CV6241 Hydrogen-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. (Absolute values) ABRIDGED DATA Hydrogen-filled tetrode thyratron with ceramic envelope, featuring low jitter and low anode delay time drift. Suitable for


    Original
    PDF CX1157 CV6241) CX1157, thyratron 16 H CX1157 CV6241 E2V Technologies cx1157 thyratron 500KV