41529
Abstract: microlens array Oriel Instruments microlens
Text: MICROLENS ARRAYS 41520 Microlens Array. Square Pattern Lens Array. • ■ ■ ■ SQUARE OR HEXAGONAL True 100% fill factor Broad wavelength range; 350 to 2500 nm Variety of standard lenses Inexpensive custom designs Oriel strives to furnish our customers with the latest in
|
Original
|
|
PDF
|
Oriel Instruments
Abstract: achromat Oriel biconvex lens UV light lens detector 40330 -27 oriel 77200
Text: FOCUSING LENS ASSEMBLY ORIEL MONOCHROMATOR FOCUSING LENS ASSY. 78150 BEAM SPLITTER HOLDER SLIT PLANE 19 mm 50 mm 77330 Focusing Lens Assembly imaging the output slit of the 77200 Monochromator onto a fiber bundle. • ■ ■ Fig. 1 77330 used to collimate the input to the 78150 Beam
|
Original
|
|
PDF
|
77058
Abstract: 71893 Ge detector oriel 71898 oriel Oriel Instruments
Text: Ge 0.6 0.4 InGaAs 0.2 0.0 800 1000 1200 1400 1600 1800 Photolithography TYPICAL RESPONSIVITY A/W 0.8 Light Sources InGaAs AND GE DETECTORS DETECTORS AND APPLICATIONS This family of InGaAs and Ge detectors covers the most frequent 0.7 - 2.5 µm NIR measurement areas for these
|
Original
|
|
PDF
|
71608 detectors
Abstract: 71891 Oriel 71891 71608 77058 Oriel Instruments 71894
Text: SILICON DETECTORS Light Sources 0.4 UV-ENHANCED SILICON 0.2 VIS-IR SILICON 0.0 200 400 600 800 1000 1200 Photolithography TYPICAL RESPONSIVITY A/W 0.6 READOUT ELECTRONICS You will find many of these detectors on other pages of this catalog where they are matched with readout
|
Original
|
|
PDF
|
ms260i
Abstract: fibers Oriel MS260iTM spectrograph MS257TM 75961 75958 75954
Text: MULTI-TRACK FIBER BUNDLES Light Sources 70 50 40 200 400 600 800 1000 1200 1400 1600 1800 2000 WAVELENGTH nm Dual and 3-Track Multi-track fiber optics. Fig. 1 Transmittance of Multi-track Fiber Optics. • Dual track, 2, 3, 5 and 9 track fibers for Multitrack Spectroscopy
|
Original
|
terminated5953
MS127iTM
MS260iTM
MS257TM
ms260i
fibers
Oriel
MS260iTM
spectrograph
MS257TM
75961
75958
75954
|
PDF
|
oriel 77520
Abstract: Oriel Instruments kevlar fibers fused glass 77561
Text: FIBER OPTIC BUNDLES 60 50 HIGH GRADE FUSED SILICA 40 STANDARD GRADE FUSED SILICA 30 20 10 70 GLASS 200 300 400 Fiber Bundle at output of Research Arc Lamp Housing. • ■ Large bundle diameters for high throughput High grade fused silica transmitts down to
|
Original
|
|
PDF
|
77427
Abstract: 77532 silica Oriel Instruments
Text: RECTANGULAR TO CIRCULAR FIBER BUNDLES 70 HIGH GRADE FUSED SILICA TRANSMITTANCE % 60 50 40 GLASS 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 2000 WAVELENGTH (nm) 77200 1/4 m Monochromator with 77856 Large Slit Fiber Adapter, and Rectangular to Circular Fiber Bundle.
|
Original
|
|
PDF
|
ir detector
Abstract: Oriel Instruments
Text: TE COOLED HgCdZnTe DETECTOR SYSTEMS 11 Light Sources 9 10 8 10 2 4 6 8 Photolithography 10 10 1/2 -1 D* cm Hz W 10 Fig. 1 Responsivity of 70788/9 HgCdZnTe Detectors. • ■ ■ ■ DETECTOR SYSTEMS Both detectors include: Unpack the detector, connect it to your data acquisition
|
Original
|
|
PDF
|
40080
Abstract: 40554 40830 40209 40240 40810 41570 41815 Oriel Instruments 41049
Text: PLANO CONVEX LENSES Tc Te fP P BFL f 42015 Lens in 12750 Lens Holder and 41329 Lens in 71594 Lens Holder. • ■ ■ Collimating or focusing lenses Various sizes and focal lengths available Fused silica models transmit down to 190 nm Plano convex lenses are used to collimate diverging light
|
Original
|
|
PDF
|
photodiode germanium
Abstract: Oriel Instruments Germanium Photodiodes Germanium 78250 70701 2. germanium
Text: böl5T77 GOOMGMT T ORIEL CORP lJRIEIM GERMANIUM DETECTORS BIASED OPERATION You can bias these detectors to 10 V for higher frequency operation 10 MHz . Biased- detectors also give a voltage output suitable for monitoring with an oscilloscope or other instruments, including A/D boards. The 70704 Bias Supply is
|
OCR Scan
|
l5T77
2x10-i2
photodiode germanium
Oriel Instruments
Germanium
Photodiodes Germanium
78250
70701
2. germanium
|
PDF
|