EPCOS EM 90 04
Abstract: epcos em-300
Text: Surge Arrester 2-Electrode-Arrester EM300XN Ordering code: B88069X0450C253 Preliminary data DC spark-over voltage 1 2) 270 … 345 V % Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 700 < 600 V V < 800
|
Original
|
PDF
|
EM300XN
B88069X0450C253
57845/VDE0845
EPCOS EM 90 04
epcos em-300
|
Untitled
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester EM300XNSMD Ordering code: T. B. D. Preliminary data DC spark-over voltage 1 2) 270 … 345 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 500 < 450 V V < 600 < 550
|
Original
|
PDF
|
EM300XNSMD
57845/VDE0845
|
epcos em-300
Abstract: B88069X0450C253
Text: Surge Arrester 2-Electrode-Arrester EM300XN Ordering code: B88069X0450C253 DC spark-over voltage 1 2) 270 … 345 V % Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 700 < 600 V V < 800 < 700 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
EM300XN
B88069X0450C253
57845/VDE0845
epcos em-300
B88069X0450C253
|
B88069X0450C253
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester EM300XN Ordering code: B88069X0450C253 DC spark-over voltage 1 2) 270 … 345 V % Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 700 < 600 V V < 800 < 700 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
EM300XN
B88069X0450C253
57845/VDE0845
B88069X0450C253
|