55290A
Abstract: No abstract text available
Text: Agilent 55290A Angular Position Measurement Kit Data Sheet The Agilent 55290A Angular Position Measurement Kit automatically calibrates rotational axes in turning and machining centers. It can perform calibrations on full, partial or multiple rotations. The purpose of the measurement is to document machine tool
|
Original
|
5290A
5290A
5990-8827EN
55290A
|
PDF
|
5529a
Abstract: x455 55290A 55290B angular position transducer 55292A
Text: 55290B Rotary Axis Measurement Kit To make angular position measurements the following products are required: Basic Laser System 5529B Angular Optics Kit (55281A) Rotary Axis Measurement Kit (55290B) Fixturing Kit (55290A-744 or later) USB Expansion Module (55292A)
|
Original
|
55290B
5529B)
5281A)
55290B)
5290A-744
5292A)
10747B
5529a
x455
55290A
angular position transducer
55292A
|
PDF
|
MAGNETICS 77439-A7
Abstract: 55930-A2 55117 core magnetics 77894-A7 77083-A7 55050-A2 55083-A2 Core 55120-A2 55930a2 58930-a2
Text: Powder Cores • Molypermalloy ■ High Flux ■ Kool Mµ Since 1949, MAGNETICS, a division of Spang & Company, has been a leading world supplier of precision, high quality, magnetic components and materials to the electronics industry. Applications for
|
Original
|
|
PDF
|
E1735A
Abstract: 5519B E1735A USB Axis Module 10753B E1738A E1736A tripod 10888A 55290B 10766A
Text: Agilent 5530 Dynamic Calibrator Data Sheet Power Requirements System Requirements Laser Head: 100 – 240 Vac, 50/60 Hz 50W during warmup , 33W (after warmup) Environmental Operating Temperature: 0 – 40°C (32 – 104°F) Optics temperature must be stabilized to ±2°C to
|
Original
|
E1735A
55290B
E1736A
E1737A
E1738A
32-bit)
0888A
5989-9712EN
5519B
E1735A USB Axis Module
10753B
tripod
10888A
10766A
|
PDF
|
MPP 55930A2
Abstract: 55050-A2 77083-A7 55120-A2 77894-A7 55930a2 77050-A7 55310-A2 58930-a2 77439-A7
Text: 0.140” 0.070” 3.56mm OD 1.78mm ID x 1.52mm HT 0.060” Core Dimensions after finish O.D. (max.) I.D. (min) HT. (max.) 4.19 mm 1.27 mm 2.16 mm Permeability (µ) 0.165 in 0.050 in 0.085 in AL +- 8% MPP 13 16 19 26 31 33 36 42 62 55140-AY 55139-AY 55138-AY
|
Original
|
55140-AY
55139-AY
55138-AY
55134-AY
55137-AY
55135-AY
MPP 55930A2
55050-A2
77083-A7
55120-A2
77894-A7
55930a2
77050-A7
55310-A2
58930-a2
77439-A7
|
PDF
|
55290A
Abstract: No abstract text available
Text: Agilent 55290B Rotary Axis Measurement Kit Data Sheet Specifications when used with the Angular Optics Kit 55281A To make angular position measurements the following products are required: Accuracy ±1.0 arc sec Repeatability ±0.8 arc sec Resolution 0.36 arc sec
|
Original
|
55290B
5281A)
55290B)
5290A-744)
5989-8213EN
55290A
|
PDF
|
55290A
Abstract: No abstract text available
Text: Agilent 5529A Dynamic Calibrator Data Sheet System Specifications Environmental Operating Temperature: 0 – 40°C 32 – 104°F Optics temperature must be stabilized to ±2°C to achieve accuracy specifications. Power Requirements Laser Head: 100 – 120 Vac, 48 – 66 Hz, and 400 Hz
|
Original
|
5964-9307E
55290A
|
PDF
|
55290A
Abstract: No abstract text available
Text: Agilent 5530 Laser Calibration System Data Sheet Power Requirements System Requirements Laser Head 100 – 240 Vac, 50/60 Hz 50 W during warmup , 33 W (after warmup) Environmental Operating Temperature 0 – 40 °C (32 – 104 °F) CAUTION LASER LIGHT DO NOT STARE INTO BEAM
|
Original
|
E1735A
55290B
E1736A
E1737A
E1738A
5989-9712EN
55290A
|
PDF
|
10887A
Abstract: 5529a 10753B "Laser Measurement" 10716A m10 1.5-6h 10774A 55292 10776A 10751D
Text: Agilent 5529A Dynamic Calibrator Data Sheet System Specifications Environmental Operating Temperature: 0 – 40°C 32 – 104°F Optics temperature must be stabilized to ±2°C to achieve accuracy specifications. Power Requirements Laser Head: 100 – 120 Vac, 48 – 66 Hz, and 400 Hz
|
Original
|
5964-9307E
10887A
5529a
10753B
"Laser Measurement"
10716A
m10 1.5-6h
10774A
55292
10776A
10751D
|
PDF
|