Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    022699 Search Results

    SF Impression Pixel

    022699 Price and Stock

    3M Interconnect 7100226993

    TRIZACTCLOTH 237AA A65 X-WEIGHT
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey 7100226993 Bulk 1
    • 1 $2076.79
    • 10 $2076.79
    • 100 $2076.79
    • 1000 $2076.79
    • 10000 $2076.79
    Buy Now
    Avnet Americas 7100226993 Bulk 4 Weeks 1
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    EDAC Inc 802-022-699-205

    302 SERIES (.05" (1.27MM) CONTAC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey 802-022-699-205 Tube 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 $4.72369
    • 10000 $4.72369
    Buy Now

    EDAC Inc 802-022-699-201

    302 SERIES (.05" (1.27MM) CONTAC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey 802-022-699-201 Tube 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 $4.6579
    • 10000 $4.6579
    Buy Now

    TE Connectivity 55PC6000-22-6-9-9-9

    CABLE 2COND 22AWG WHITE SHLD
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey 55PC6000-22-6-9-9-9 Bulk 2,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $2.43559
    Buy Now

    TE Connectivity 55A6470-22-6-9-9CS2102

    CABLE 2COND 22AWG WHITE SHLD
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey 55A6470-22-6-9-9CS2102 Bulk 2,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 $10.40696
    Buy Now

    022699 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    SI-MAG3SM

    Abstract: No abstract text available
    Text: GM-FA-10J Gate Monitoring Safety Module 24V ac/dc operation, 1- or 2-Channel Input Original Instructions • Monitors one or two safety switches for a contact failure or wiring fault • Two output switching channels for connection to control-reliable power interrupt circuits


    Original
    GM-FA-10J UL991, EN954-1) SI-MAG3SM PDF

    force piezo signal conditioning circuit for 4-20

    Abstract: vacuum tube applications data book 41a Hall Effect Magnetic Sensors germanium
    Text: PRESSURE CONVERSION TABLE Atmos Bars Dynes/cm2 In of Hg 0° C In of H20 (4° C) K grams/ meter2 Lb/in2 psi Lb/ft2 mm of Hg torr Microns Pascals 1 9.86923 x 10-1 9.86923 x 10-7 3.34207 x 10-2 2.458 x 10-3 9.678 x 10-5 0.068046 4.7254 x 10-4 1.316 x 10-3 1.316


    Original
    896ezoelectric force piezo signal conditioning circuit for 4-20 vacuum tube applications data book 41a Hall Effect Magnetic Sensors germanium PDF

    Untitled

    Abstract: No abstract text available
    Text: ES-FA-6G 1-Channel Emergency Stop Safety Module 24V ac/dc operation E-Stop Safety Module Features • Monitors one single-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault • Three output switching channels for connection to control-reliable power


    Original
    UL991, EN418, EN954-1 EN418 PDF

    siemens mccb

    Abstract: SIEMENS circuit breakers mccb circuit breaker siemens mccb datasheet MCCB for welding application SWITCHGEAR IEEE STD 1015-1997 siemens electrical breaker CIRCUIT BREAKER siemens mccb circuit breaker DATASHEET
    Text: Recognized as an American National Standard ANSI IEEE Std 1015-1997 IEEE Recommended Practice for Applying Low-Voltage Circuit Breakers Used in Industrial and Commercial Power Systems Sponsor Power Systems Protection Committee of the Industrial and Commercial Power Systems Department


    Original
    PDF

    SO-DIMM

    Abstract: No abstract text available
    Text: 4M x 32 Bit 3.3V UNBUFFERED EDO SODIMM Extended Data Out EDO DRAM SMALL OUTLINE DIMM 32400sEDM4G02TA 72 Pin 4Mx32 EDO SODIMM Unbuffered, 4k Refresh, 3.3V Pin Assignment General Description Pin# Front Side Pin# Back Side 1 GND 2 DQ0 3 DQ1 4 DQ2 5 DQ3 6 DQ4


    Original
    32400sEDM4G02TA 4Mx32 DS613-1 SO-DIMM PDF

    RIA Contacts Type 329

    Abstract: RPA-C2-10 RP-LS42F-75L RP-LS42F ISO12100-1 ISO13849-1 ISO13850 ISO12100-2 NFPA79
    Text: Rope Pull Emergency Stop Switches RP-LS42F-75L. Series 42 mm Latching Switches with Rope Actuators Features •  Positive-opening safety contacts IEC 60947-5-1 , not dependent upon springs • Contacts latch open when rope is pulled; requires manual reset


    Original
    RP-LS42F-75L. RP-LS42F-75LE RP-LS42F-75LF RIA Contacts Type 329 RPA-C2-10 RP-LS42F-75L RP-LS42F ISO12100-1 ISO13849-1 ISO13850 ISO12100-2 NFPA79 PDF

    Untitled

    Abstract: No abstract text available
    Text: Model EM-T-7A Extension Module One- or two-channel control for use with a Primary Safety Device Features R R C • Extension Module provides additional safety outputs for a Primary Safety Device for example, an E-stop Safety Module or a 2-hand control module , if controlled


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: STB Self-Checking Optical Touch Buttons † Self-Checking Ergonomic Actuating Devices Features • Diverse-redundant microcontroller-based photoelectric touch buttons • Continuous internal self-checking operation • Ergonomically designed to eliminate hand, wrist and arm stresses associated with


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: SSM-FM-11A. Safe Speed Monitoring Modules Datasheet For over-speed, under-speed, and zero-speed detection • • • • • • • • • • • • • Dual-channel redundancy Monitors 2 sensors with PNP outputs Monitors rotation rpm or linear movement


    Original
    SSM-FM-11A. PDF

    EN894

    Abstract: SC22-3 EN574 ISO13851 STBVR81 MBCC-512
    Text: STB Self-Checking Optical Touch Buttons † Self-Checking Ergonomic Actuating Devices Features • Diverse-redundant microcontroller-based photoelectric touch buttons • Continuous internal self-checking operation • Ergonomically designed to eliminate hand, wrist and arm stresses associated with


    Original
    PDF

    AT-GM-13A

    Abstract: EN292 AT-HM-13A tr121001 EN954-1 ISO13849-1 ISO13855 brake failure indicator two-hand S13-S22
    Text: DUO-TOUCH SG Two-Hand Control Modules Models AT-GM-13A and AT-HM-13A, for use with two actuating devices Features • Diverse-redundant microcontrollers • Supplies power and monitors two Banner STB Self-Checking Optical Touch Buttons, or two mechanical push buttons


    Original
    AT-GM-13A AT-HM-13A, AT-HM-13A EN292 tr121001 EN954-1 ISO13849-1 ISO13855 brake failure indicator two-hand S13-S22 PDF

    SI-MAG3SM

    Abstract: circuit of GREEN HOUSE ROBOT EN954-1 transformer 2 mva IEC 60998 AC24V
    Text: GM-FA-10J Gate Monitoring Safety Module 24V ac/dc operation, 1- or 2-Channel Input Original Instructions Features • Monitors one or two safety switches for a contact failure or wiring fault • Two output switching channels for connection to control-reliable power interrupt circuits


    Original
    GM-FA-10J UL991, EN954-1) Sa11016 SI-MAG3SM circuit of GREEN HOUSE ROBOT EN954-1 transformer 2 mva IEC 60998 AC24V PDF

    CRC16-polynomial circuit design

    Abstract: DS1921 DS1921L-F5 DS9092 DS9093A DS9093RA DS9096P DS9101 time alarm DS1921
    Text: DS1921 PRELIMINARY A DALLAS W SEM ICONDUCTOR SPECIAL FEATURES • Digital therm om eter m easures tem perature from -4 0 ° C to +70°C in 0.5°C increm ents • Tem perature conversion accuracy ± 1 °C from -2 0 °C to +70°C at tim e of calibration • Real Tim e C lock/calendar in BCD form at counts


    OCR Scan
    DS1921 CRC16-polynomial circuit design DS1921 DS1921L-F5 DS9092 DS9093A DS9093RA DS9096P DS9101 time alarm DS1921 PDF

    Untitled

    Abstract: No abstract text available
    Text: GM-FA-10J Gate Monitoring Safety Module 24V ac/dc operation, 1- or 2-Channel Input Original Instructions • Monitors one or two safety switches for a contact failure or wiring fault • Two output switching channels for connection to control-reliable power interrupt circuits


    Original
    GM-FA-10J UL991, EN954-1) PDF

    a2324

    Abstract: No abstract text available
    Text: E-Stop฀Safety฀Modules฀with฀Adjustable฀Delay Features •฀ ฀Selectable฀Auto-Reset฀or฀monitored฀Manual฀Reset. •฀฀Auto฀or฀manual฀power-up


    Original
    ES-TN-14H5à ES-TN-14H6à a2324 PDF

    Untitled

    Abstract: No abstract text available
    Text: ES-FA-9AA and ES-FA-11AA E-Stop Safety Modules With 3 normally open safety outputs or 2 normally open safety outputs and 1 normally closed auxiliary output Original Instructions • Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and positive-opening safety switches used for guard/gate interlocking


    Original
    ES-FA-11AA S11-S12 S21-S22 PDF

    Untitled

    Abstract: No abstract text available
    Text: SM-xA-5A Safety Mat Monitoring Modules SM-GA-5A 12-24V dc / 115V ac operation and SM-HA-5A (12-24V dc / 230V ac operation) • Monitors one 4-wire safety mat, or multiple mats in series • Selectable Automatic (Auto) Reset or Monitored Manual Reset • Input monitoring circuit incorporates redundant microprocessors


    Original
    2-24V PDF

    Untitled

    Abstract: No abstract text available
    Text: E-Stop฀Safety฀Modules฀with฀Adjustable฀Delay Features •฀ ฀Selectable฀Auto-Reset฀or฀monitored฀Manual฀Reset. •฀฀ Auto฀or฀manual฀power-up


    Original
    P/NN63443 PDF

    125A6A

    Abstract: 125A10B
    Text: Replacement - Tube Guitar Output 1750 Series TUBE GUITAR AMPLIFIER - OUTPUT TRANSFORMERS Guitar Amp • • • • Designed for drop in replacement of original tube guitar ampliier output transformers. Physically, parts were designed to look similar to original factory units (where possible).


    Original
    125A20B 125A35A 125A10B 125C1A 125A6A 125A10B PDF

    Chokes

    Abstract: 125A13A 125A6A 125C1A 125P34A
    Text: Replacement - Tube Guitar Output 1750 Series TUBE GUITAR AMPLIFIER - OUTPUT TRANSFORMERS Guitar Amp • Designed for drop in replacement of original tube guitar amplifier output transformers. • Physically, parts were designed to look similar to original factory units (where possible).


    Original
    1750C 125C1A Chokes 125A13A 125A6A 125C1A 125P34A PDF

    EN418

    Abstract: EN60204-1 EN954-1 IEC60947-5-1 UL991 EN292-1
    Text: Emergency Stop Safety Modules Model ES-FA-9AA 24V ac/dc, 3 N/O Features • Monitors one dual-channel normally closed emergency stop switch circuit for a contact failure or wiring fault • The ES-FA-9AA has three output switching channels for connection to controlreliable power interrupt circuits


    Original
    UL991, EN418) EN954-1) IEC/EN60204-1 EN418 EN60204-1 EN954-1 IEC60947-5-1 UL991 EN292-1 PDF

    Project Report of fire alarm

    Abstract: Westinghouse chiller ELEVATOR LOGIC CONTROL complete projects plc based automatic car parking system westinghouse switchgear NFPA-70B report on project of Elevator system using PLC light sensitive burglar alarm project westinghouse switchgear 1976 burglar alarm system abstract
    Text: Recognized as an American National Standard ANSI IEEE Std 241-1990 (Revision of IEEE Std 241-1983) IEEE Recommended Practice for Electric Power Systems in Commercial Buildings Sponsor Power Systems Engineering Committee of the IEEE Industry Applications Society


    Original
    70E-1988, CY-70HB90, CP-46-85, Project Report of fire alarm Westinghouse chiller ELEVATOR LOGIC CONTROL complete projects plc based automatic car parking system westinghouse switchgear NFPA-70B report on project of Elevator system using PLC light sensitive burglar alarm project westinghouse switchgear 1976 burglar alarm system abstract PDF

    resistive screen controlled robot

    Abstract: inductive proximity sensor npn perimeter beam sensor circuit diagram B1117 10GH EN954-1 ossd output working principle scanner block diagram MMD-TA-12B B1116
    Text: Muting Module Models MMD-TA-11B and MMD-TA-12B Instruction Manual Features • Compact, 67.5 mm DIN-mounted housing with plug-in terminal blocks. • For use with EZ-SCREEN Output Signal Switching Device OSSD outputs or MINI-SCREEN®, MICROSCREEN®, MACHINE-GUARD®, or other safety


    Original
    MMD-TA-11B MMD-TA-12B resistive screen controlled robot inductive proximity sensor npn perimeter beam sensor circuit diagram B1117 10GH EN954-1 ossd output working principle scanner block diagram MMD-TA-12B B1116 PDF

    EN574

    Abstract: ISO13851 OTBVR81 EN954-1 ISO13849-1 ISO13855
    Text: DUO-TOUCH – Two-Hand Control Modules Models AT-FM-2A, AT-AM-2A, and AT-BM-2A, for Use with Two Actuating Devices Features • Two redundant, forced-guided mechanically linked output contacts rated at 4 A • One auxiliary N.C. relay output rated at 0.5 A


    Original
    45-mm-wide EN574 ISO13851 OTBVR81 EN954-1 ISO13849-1 ISO13855 PDF