The maximum current rating of the VND600SPTR-E is 1.5 A per channel, with a maximum total current of 3 A.
The VND600SPTR-E requires a 5 V power supply, and it's recommended to use a decoupling capacitor of at least 100 nF between the VCC and GND pins to ensure stable operation.
The EN (enable) pin is used to enable or disable the device. When the EN pin is high, the device is enabled, and when it's low, the device is disabled.
The VND600SPTR-E can be configured for half-bridge or full-bridge operation by connecting the corresponding pins (HB/ FB) to VCC or GND. Refer to the datasheet for specific pin connections.
The thermal resistance (Rth) of the VND600SPTR-E is 25°C/W (junction-to-ambient) and 10°C/W (junction-to-case).