The maximum operating temperature range for VIPER20(022Y) is -40°C to 150°C.
To ensure proper cooling, make sure to provide a heat sink with a thermal resistance of less than 10°C/W and ensure good airflow around the device.
To minimize EMI, use a multi-layer PCB with a solid ground plane, keep the layout symmetrical, and use a shielded transformer. Also, keep the high-frequency components away from the low-frequency components.
Select a transformer with a turns ratio that matches the input and output voltage requirements, and ensure the transformer's saturation current is higher than the peak current of the VIPER20(022Y).
The recommended input capacitor value is 1-10uF, depending on the input voltage and current requirements. A higher capacitance value can help reduce input voltage ripple.