The maximum operating temperature range for the VCT60US24 is -40°C to +100°C, with a derating of 2.5% per °C above 80°C.
-
Yes, the VCT60US24 is designed to operate in humid environments, with a humidity range of 5-95% RH, non-condensing.
-
The MTBF rating for the VCT60US24 is 1,500,000 hours, calculated according to MIL-HDBK-217F.
-
Yes, the VCT60US24 is compliant with UL60950-1, EN60950-1, and IEC60950-1 safety standards.
-
Yes, the VCT60US24 is designed to operate in environments with vibration levels up to 10G, 10-200Hz, and can withstand shock levels up to 50G, 11ms.