The maximum capacitance tolerance for the input filter capacitors is ±20%.
The VCT60US15 is rated for operation up to 80°C, but derating is required above 60°C. Consult the datasheet for derating curves.
XP Power recommends a PCB layout with a solid copper ground plane and thermal vias to the heat sink for optimal thermal performance.
Yes, multiple VCT60US15 modules can be paralleled to increase power output, but ensure that the input and output connections are properly connected and decoupled.
The minimum input voltage required for the VCT60US15 to operate is 90VAC, but the recommended minimum input voltage is 100VAC for optimal performance.