The UC2524ADW requires careful layout and placement to ensure proper operation. TI recommends placing the IC close to the input capacitors, using a star-ground configuration, and keeping the high-current paths short and wide.
To ensure stability, make sure to follow the recommended compensation network values, use a sufficient output capacitor, and avoid excessive input capacitance. Also, ensure the feedback loop is properly compensated and the gain-bandwidth product is within the recommended range.
The UC2524ADW can handle input voltages up to 40V, but it's recommended to keep the input voltage below 35V to ensure reliable operation and prevent damage to the IC.
The UC2524ADW is rated for operation up to 125°C, but it's recommended to derate the output current and voltage as the temperature increases to ensure reliable operation and prevent overheating.
Use external overcurrent protection devices, such as fuses or current-sensing resistors, and overvoltage protection devices, such as zener diodes or TVS diodes, to protect the UC2524ADW from damage due to overcurrent and overvoltage conditions.