The maximum capacitance load for the TR05S3V3 is 10uF. Exceeding this value may affect the stability of the output voltage.
While the TR05S3V3 is rated for operation up to 85°C, it's recommended to derate the output current by 2.5% per degree above 60°C to ensure reliable operation.
To ensure EMC, XP Power recommends using a 1uF ceramic capacitor between the input and output pins, and a 10nF capacitor between the output pin and GND. Additionally, keep the output cables as short as possible and use twisted pairs for input and output connections.
While the datasheet specifies a minimum input voltage of 3.5V, XP Power recommends an input voltage range of 4.5V to 5.5V for optimal performance and reliability.
Yes, you can parallel multiple TR05S3V3 modules to increase the output current. However, ensure that each module has its own input capacitor and that the output connections are made with low-impedance cables to minimize voltage drops.