The maximum clock frequency that can be used with the internal oscillator is 10 MHz. However, it's recommended to use a crystal oscillator or an external clock source for more accurate and stable clocking.
The flash memory can be configured to store both code and data by using the Flash Memory Control Registers (FMCR) to set the flash memory partitioning. The FMCR registers allow you to define the boundaries between the code and data sections.
The maximum current that can be sourced or sunk by the GPIO pins is 4 mA. However, it's recommended to limit the current to 2 mA to ensure reliable operation and to prevent overheating.
The TMS320F243PGE has a built-in watchdog timer that can be enabled and configured using the Watchdog Timer Control Registers (WTCSR). The watchdog timer can be used to reset the device in case of a software fault or hang.
The minimum voltage required for the ADC to operate correctly is 2.7 V. The ADC requires a minimum voltage of 2.7 V to ensure accurate conversions.