The maximum operating temperature range for the TMS320C28342ZFET is -40°C to 105°C (ambient temperature). However, it's recommended to operate within -40°C to 85°C for optimal performance and reliability.
The clock settings for the TMS320C28342ZFET can be configured using the Clock Enable (CLKEN) register, Clock Source (CLKSRC) register, and the PLL Control (PLLCTL) register. Refer to the device's user guide and the clock module chapter for detailed information.
The maximum frequency of the PWM outputs on the TMS320C28342ZFET is 100 MHz. However, the actual frequency achievable depends on the specific PWM module, clock frequency, and system configuration.
Yes, the TMS320C28342ZFET is suitable for motor control applications due to its high-performance processing capabilities, advanced peripherals, and specialized motor control peripherals such as the ePWM and eCAP modules.
The TMS320C28342ZFET has a built-in watchdog timer module that can be configured to reset the device in case of a software fault or hang. The watchdog timer can be enabled and configured using the Watchdog Timer Control (WDTC) register and the Watchdog Timer Reload (WDTREL) register.