TMP75CIDGKR Frequently Asked Questions (FAQs)
-
The TMP75CIDGKR has an accuracy of ±1°C from -20°C to 100°C and ±2°C from -40°C to 125°C.
-
The TMP75CIDGKR defaults to 12-bit resolution. To configure it for 13-bit resolution, set the RES bit in the configuration register to 1.
-
The conversion time for the TMP75CIDGKR is 30 ms for 12-bit resolution and 60 ms for 13-bit resolution.
-
Yes, the TMP75CIDGKR can be used for remote temperature sensing using a diode-connected transistor or a thermistor.
-
The TMP75CIDGKR's open-drain output requires a pull-up resistor to VCC. The recommended pull-up resistor value is 1 kΩ to 10 kΩ.