The TMP75AIDRG4 has an accuracy of ±1°C from -20°C to 100°C and ±2°C from -40°C to 125°C.
The TMP75AIDRG4 defaults to 12-bit resolution. To configure it for 13-bit resolution, set the RES bit in the configuration register (address 0x01) to 1.
The conversion time for the TMP75AIDRG4 is approximately 30 ms for 12-bit resolution and 60 ms for 13-bit resolution.
The TMP75AIDRG4 has an alert function that can be configured to trigger an interrupt when the temperature exceeds a set threshold. The alert threshold is set using the T_HIGH and T_LOW registers (addresses 0x02 and 0x03).
The power consumption of the TMP75AIDRG4 is typically 10 μA in shutdown mode and 150 μA in active mode.