TMP421AIDCNTG4 Frequently Asked Questions (FAQs)
-
The typical power consumption of the TMP421AIDCNTG4 is 1.5 μA (max) when operating at 3.3 V and 1.2 μA (max) when operating at 2.7 V.
-
The TMP421AIDCNTG4 has an accuracy of ±1°C (max) over the temperature range of -20°C to 125°C.
-
The response time of the TMP421AIDCNTG4 is typically 30 ms (max) for a 10°C step change in temperature.
-
Yes, the TMP421AIDCNTG4 can operate in high-temperature environments up to 150°C (max).
-
No, the TMP421AIDCNTG4 is not compatible with 5 V systems. It is designed to operate at supply voltages between 2.7 V and 3.6 V.