The TMP100MDBVREP can operate from -40°C to 125°C, but the accuracy of the temperature measurement is specified from -20°C to 100°C.
The TMP100MDBVREP defaults to 12-bit resolution. To configure it for 13-bit resolution, set the RES bit in the configuration register (address 0x01) to 1.
The conversion time for the TMP100MDBVREP is approximately 30 ms for a 12-bit conversion and 60 ms for a 13-bit conversion.
Yes, the TMP100MDBVREP supports multi-drop bus configuration. Up to eight devices can be connected to the same bus, each with a unique address set by the A0, A1, and A2 pins.
The TMP100MDBVREP has an alert function that can be configured to trigger an interrupt when the temperature exceeds a set threshold. The alert function is enabled by setting the ALERT_EN bit in the configuration register (address 0x01).