The recommended power-up sequence is to apply VDD first, followed by VDDIO, and then the clock signal. This ensures proper initialization of the device.
The TLV320AIC3100 can be configured for master or slave mode by setting the M/S bit in the Control Register (CR) to 0 for master mode or 1 for slave mode.
The TLV320AIC3100 supports clock frequencies up to 50 MHz.
The TLV320AIC3100 has a built-in microphone bias voltage generator that can be enabled by setting the MIC_BIAS_EN bit in the Control Register (CR). The bias voltage can be set to 1.5V, 2.0V, or 2.5V using the MIC_BIAS_SEL bits.
The PLL_BYPASS pin allows the user to bypass the internal phase-locked loop (PLL) and use an external clock source instead.