The TLC5922DAPG4 can source up to 25mA per output, but it's recommended to limit it to 10mA to ensure reliable operation.
Make sure to follow the power-up sequence specified in the datasheet, and ensure that the VCC pin is powered up before the VDD pin. Also, wait for at least 1ms after power-up before sending any data to the device.
The TLC5922DAPG4 can operate with clock frequencies up to 30MHz, but it's recommended to limit it to 10MHz to ensure reliable operation and minimize power consumption.
The TLC5922DAPG4 has built-in error detection and fault protection mechanisms, such as overcurrent protection and thermal shutdown. In case of an error, the device will automatically shut down and can be reset by cycling the power or using the reset pin.
The TLC5922DAPG4 is rated for operation up to 85°C, but it's recommended to derate the output current and clock frequency at higher temperatures to ensure reliable operation and minimize power consumption.