The maximum operating temperature range for the TL1963A-25DCYT is -40°C to 125°C.
To ensure stability, a minimum output capacitance of 10uF is recommended, and the output capacitor should be placed as close to the output pin as possible.
The maximum input voltage that the TL1963A-25DCYT can handle is 28V.
Yes, the TL1963A-25DCYT is qualified for automotive and industrial applications, and it meets the requirements for high-reliability applications.
The output voltage of the TL1963A-25DCYT can be calculated using the formula: Vout = (R1/R2) * (Vin - Vref), where R1 and R2 are the resistors in the feedback network, Vin is the input voltage, and Vref is the reference voltage.