The recommended operating voltage range for the TCA6408ARGTR is 1.65V to 5.5V.
The TCA6408ARGTR can be configured for I2C or SMBus interface by setting the A0 and A1 address pins. For I2C, A0 and A1 should be connected to GND, and for SMBus, A0 should be connected to VCC and A1 to GND.
The maximum frequency of the clock input for the TCA6408ARGTR is 400 kHz.
The TCA6408ARGTR can be reset by pulling the RESET pin low for at least 1 ms.
The power consumption of the TCA6408ARGTR is typically 1.5 μA in standby mode and 150 μA in active mode.