The maximum operating junction temperature of the T70HFL100S05 is 150°C, but it's recommended to keep it below 125°C for reliable operation.
Proper cooling can be achieved by using a heat sink with a thermal resistance of less than 1°C/W, and ensuring good airflow around the device. The heat sink should be attached using a thermal interface material with a thermal conductivity of at least 1 W/m-K.
The recommended gate drive voltage for the T70HFL100S05 is between 10V and 15V, with a maximum gate-source voltage of 20V.
Yes, the T70HFL100S05 can be used in a parallel configuration, but it's essential to ensure that the devices are matched in terms of their electrical characteristics, and that the gate drive signals are properly synchronized to prevent shoot-through currents.
The maximum allowable dv/dt for the T70HFL100S05 is 10 kV/μs, but it's recommended to limit it to 5 kV/μs or less to prevent voltage overshoots and ensure reliable operation.