The STR711FR2T6 can operate in a temperature range of -40°C to 85°C.
The clock speed of the STR711FR2T6 can be configured using the Clock Control Register (CKCU). The clock speed can be set to 32 kHz, 4 MHz, or 8 MHz.
The maximum current consumption of the STR711FR2T6 is 20 mA at 3.3V and 25°C.
The ADC on the STR711FR2T6 can be used by configuring the ADC Control Register (ADC_CR) and the ADC Configuration Register (ADC_CFGR). The ADC can be triggered by a software trigger or an external trigger.
Yes, the STR711FR2T6 can be used with an external crystal oscillator. The external crystal oscillator can be connected to the OSC_IN and OSC_OUT pins.