The recommended operating voltage range for STK15C88-NF25 is 2.7V to 3.6V.
The power-up sequence for STK15C88-NF25 is critical. It is recommended to power up VCC before VPP, and VCC should be stable before applying clock signals.
The maximum clock frequency supported by STK15C88-NF25 is 100 MHz.
A reliable reset mechanism can be implemented by using an external reset IC or a power-on reset circuit that ensures a clean reset signal to the device.
When designing a PCB with STK15C88-NF25, it is essential to follow good layout practices, such as separating analog and digital signals, using decoupling capacitors, and minimizing signal routing near the device.