The SPC56EC64L7B9E0Y has an operating temperature range of -40°C to 125°C.
The clock settings for the SPC56EC64L7B9E0Y can be configured using the Clock Generation Unit (CGU) module. The CGU module allows you to select the clock source, configure the clock frequency, and enable/disable clock outputs. You can refer to the device's reference manual for more information on clock configuration.
The maximum frequency of the CPU is 120 MHz, and the maximum frequency of the peripherals is 60 MHz.
The SPC56EC64L7B9E0Y has a built-in watchdog timer (WDT) module that can be used to reset the device in case of a software fault. The WDT can be configured using the WDT control register, and the timeout period can be set using the WDT timer register. You can refer to the device's reference manual for more information on WDT configuration.
The power consumption of the SPC56EC64L7B9E0Y depends on the operating mode and frequency. In active mode, the typical current consumption is around 50 mA at 120 MHz. In sleep mode, the typical current consumption is around 10 mA. You can refer to the device's datasheet for more information on power consumption characteristics.