The recommended operating voltage range for the SN74LVC3G14DCURG4 is 1.65 V to 5.5 V.
To ensure the Schmitt trigger inputs are properly biased, connect a pull-up or pull-down resistor to the input pin, and ensure the input voltage is within the recommended operating range.
The maximum frequency of operation for the SN74LVC3G14DCURG4 is 100 MHz.
To handle power sequencing, ensure that the VCC pin is powered up before the input signals, and that the input signals are stable before the clock signal is applied.
The maximum output current that the SN74LVC3G14DCURG4 can sink or source is 24 mA.