The maximum operating frequency of the SN74HC240PW is 50 MHz, but it can vary depending on the output load and supply voltage.
It is recommended to power up the VCC pin before the input signals and power down the VCC pin after the input signals to prevent unwanted output states.
The recommended operating temperature range for the SN74HC240PW is -40°C to 85°C, but it can operate up to 125°C with reduced performance.
It is recommended to use a 0.1 μF ceramic capacitor between the VCC pin and GND pin, and a 10 μF electrolytic capacitor between the VCC pin and GND pin for proper decoupling.
The maximum output current that the SN74HC240PW can sink or source is 25 mA per pin, but it is recommended to limit the output current to 10 mA per pin for reliable operation.