The S29GL512S11DHA023 has a minimum of 100,000 erase cycles per sector, and a total of 2,000,000 erase cycles per device.
To transition from active to standby power mode, the CE# pin should be driven high, and the OE# and WE# pins should be driven high or left floating. The device will then enter standby power mode, reducing power consumption.
The recommended method is to use the RY/BY# pin, which goes low during a program or erase operation and returns high when the operation is complete. Alternatively, the DQ7 pin can be used to detect the end of a program or erase operation.
If the device is powered up with a voltage below the minimum specified voltage, it may not function correctly. To avoid this, ensure that the power supply voltage is within the specified range (2.7V to 3.6V) before attempting to access the device.
The WP# pin is used to enable or disable the write protection feature. When the WP# pin is driven low, the device is write-protected, and when it is driven high or left floating, the device is not write-protected.