The maximum operating temperature range for the S29GL512S10GHI020 is -40°C to +85°C.
The hold signal (HOLD#) should be asserted low to pause the current operation and de-asserted high to resume the operation. During hold, the device will tri-state its outputs and ignore any input signals.
The write protect (WP#) signal is used to prevent accidental writes to the device. When WP# is asserted low, the device will ignore any write commands and protect the contents of the memory.
The device density and configuration can be determined by reading the device ID and configuration registers. The device ID is read using the JEDEC ID command (0x90), and the configuration registers are read using the Read Configuration Register command (0x35).
The recommended power-up sequence is to apply VCC first, followed by VPP (if used), and then the clock signal. The device should be in a reset state (RST# asserted low) during power-up.