The maximum operating temperature range for the S29GL512P10FAIR12 is -40°C to +85°C.
-
The hold signal (HOLD#) should be asserted low to pause the current operation and de-asserted high to resume the operation.
-
The write protect (WP#) signal is used to prevent accidental writes to the device. When WP# is low, the device is write-protected.
-
To perform a sector erase operation, send the erase command (0x20) followed by the sector address to be erased.
-
The recommended power-up sequence is to apply VCC first, followed by VPP, and then the clock signal.