The maximum operating temperature range for the S29GL128P10TFI010 is -40°C to +85°C.
The HOLD# signal should be used to pause the device during a read or write operation, while the OE# signal should be used to tri-state the output buffers during a read operation.
The WP# signal is used to prevent accidental writes to the device. When WP# is low, the device is in a protected state and writes are inhibited.
To perform a sector erase operation, send the erase command (0x20) followed by the sector address. The device will then erase the entire sector.
The main difference is the access time: the S29GL128P10TFI010 has an access time of 10ns, while the S29GL128P10TFI020 has an access time of 20ns.