The maximum operating frequency of the S29GL01GS10FHI010 is 133 MHz.
The hold signal (HOLD#) is used to pause the current operation. To handle it, assert HOLD# low to pause the operation, and then deassert it to resume the operation.
The write protect (WP#) signal is used to prevent accidental writes to the device. When WP# is low, the device is in write-protect mode, and all write operations are inhibited.
To perform a sector erase operation, send the erase command (0x60h) followed by the sector address. The device will then erase the entire sector.
The main difference is the operating voltage range. The S29GL01GS10FHI010 operates from 2.7V to 3.6V, while the S29GL01GS10FHIV10 operates from 1.8V to 3.6V.