The recommended operating voltage range for the S29GL01GP13FFIV10 is 2.7V to 3.6V.
The hold signal (HOLD#) should be asserted low to pause the current operation and de-asserted high to resume the operation.
The write protect (WP#) signal is used to prevent accidental writes to the device. When WP# is low, the device is in write-protect mode, and all write operations are inhibited.
To perform a sector erase operation, send the erase command (0x60) followed by the sector address. The device will then erase the entire sector.
The maximum number of erase cycles for the S29GL01GP13FFIV10 is 100,000 cycles per sector.