The maximum operating temperature range for the S-8533A15AFT-TB-U is -40°C to +105°C.
To ensure stable output voltage, it's recommended to use a 10uF or larger ceramic capacitor for the output capacitor (COUT) and a 1uF or larger ceramic capacitor for the input capacitor (CIN).
The minimum input voltage required for the S-8533A15AFT-TB-U to operate is 2.5V.
The S-8533A15AFT-TB-U has a maximum output current of 150mA. If your application requires higher current, you may need to consider a different voltage regulator or use multiple S-8533A15AFT-TB-U devices in parallel.
The output voltage of the S-8533A15AFT-TB-U can be calculated using the formula: VOUT = 1.5V x (1 + (R1/R2)), where R1 and R2 are the resistors used to set the output voltage.