Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RS-150-3.3 datasheet by Mean Well

    • PWR SPLY,SW,ENCL,99W, 3.3V@30A,UL/CUL/TUV/CE
    • Original
    • Yes
    • Yes
    • Active
    • EAR99
    • Powered by Findchips Logo Findchips

    RS-150-3.3 datasheet preview

    RS-150-3.3 Frequently Asked Questions (FAQs)

    • The maximum ambient temperature for the RS-150-3.3 is 50°C (122°F) with derating, and 40°C (104°F) without derating.
    • Yes, the RS-150-3.3 is designed to operate in a humidity range of 20% to 90% RH, non-condensing. However, it's recommended to take precautions to prevent moisture ingress.
    • The hold-up time for the RS-150-3.3 is approximately 16ms at 230VAC input and full load.
    • Yes, the RS-150-3.3 can be used in a redundant configuration, but it's recommended to use a diode ORing circuit or a redundancy module to ensure proper operation.
    • The MTBF for the RS-150-3.3 is approximately 550,000 hours at 25°C (77°F) ambient temperature, calculated according to MIL-HDBK-217F.