The recommended operating temperature range for the RHRG3050CC is -55°C to 150°C, although it can withstand storage temperatures from -65°C to 175°C.
To ensure proper biasing, the RHRG3050CC requires a Vcc supply voltage between 3.5V and 5.5V, and a Vee supply voltage of -5.5V to -3.5V. Additionally, the input voltage should be within the specified range of -2.5V to Vcc + 0.5V.
The maximum power dissipation for the RHRG3050CC is 1.5W, and it is essential to ensure proper heat sinking to prevent overheating and damage to the device.
Yes, the RHRG3050CC is designed to be radiation-hardened and can withstand total ionizing dose (TID) effects up to 100 krad(Si). However, it is essential to consult the datasheet and application notes for specific radiation requirements and testing.
The RHRG3050CC has built-in ESD protection, but it is still essential to follow proper ESD handling procedures, such as using an ESD wrist strap or mat, to prevent damage to the device.