The maximum ambient temperature for the PPS-200-12 is 40°C (104°F) for normal operation, and 30°C (86°F) for full load operation.
Yes, the PPS-200-12 can operate up to 5000 meters (16,400 feet) above sea level, but the output power may be derated.
The hold-up time for the PPS-200-12 is approximately 10ms, which means the output voltage will remain stable for at least 10ms in the event of an input power failure.
Yes, you can parallel up to 3 units of PPS-200-12 for higher power output, but you need to ensure proper synchronization and current sharing between the units.
The MTBF for the PPS-200-12 is approximately 550,000 hours, calculated according to MIL-HDBK-217F.