The recommended power-on sequence is to apply VCC first, followed by AVCC, and then DVCC. This ensures proper internal biasing and prevents latch-up.
-
Use a 1 kΩ to 2 kΩ resistor in series with the analog input signal to prevent overvoltage and ensure proper signal termination.
-
The maximum clock frequency for the PCM55HP is 50 MHz. Exceeding this frequency may result in reduced performance or incorrect operation.
-
Use a 10 kΩ to 22 kΩ pull-up resistor on the digital output signals to ensure proper signal levels and prevent signal degradation.
-
The recommended operating temperature range for the PCM55HP is -40°C to 85°C. Operating outside this range may affect performance or reliability.