The recommended power-up sequence is to apply VDD first, followed by AVDD, and then DVDD. This ensures that the internal voltage regulators are powered up correctly.
The analog input filter should be optimized based on the specific application requirements. A good starting point is to use a 1st-order RC filter with a cutoff frequency of around 100 kHz to 200 kHz. The filter components should be chosen to minimize noise and distortion.
The maximum input signal amplitude that the PCM1863DBT can handle is 2.5 Vrms. Exceeding this amplitude may result in distortion and decreased performance.
To configure the PCM1863DBT for differential input mode, connect the positive input signal to the INP pin and the negative input signal to the INN pin. Ensure that the input common-mode voltage is within the recommended range of 0.5 V to 2.5 V.
The recommended clock frequency for the PCM1863DBT is 256 fs, where fs is the sampling frequency. This ensures that the ADC operates within its specified performance range.