The recommended power-up sequence is to apply VCC first, followed by VREF, and then the clock signal. This ensures proper initialization of the device.
Use a low-pass filter with a cutoff frequency below 20 kHz to remove high-frequency noise, and ensure the input impedance is matched to the analog source. Also, use a buffer amplifier if the source impedance is high.
The maximum allowed clock jitter is 100 ps RMS. Exceeding this value can result in increased jitter in the digital output signal.
Yes, but ensure that the analog ground plane is connected to the digital ground plane at a single point, preferably near the power supply. This helps to reduce noise and improve performance.
The PCM1804 outputs data in I²S format. Ensure that the receiving device is configured to accept I²S data, and that the clock and data lines are properly synchronized.