The recommended operating voltage range for PCAL6416AHF is 1.65 V to 5.5 V, with a typical voltage of 3.3 V or 5 V.
The PCAL6416AHF can be configured for I2C or SMBus interface by setting the appropriate values for the SCL and SDA pins. For I2C, set SCL to 100 kHz or 400 kHz, and for SMBus, set SCL to 10 kHz or 100 kHz.
The maximum frequency for the PCAL6416AHF is 400 kHz for I2C and 100 kHz for SMBus.
The interrupt output of the PCAL6416AHF is an open-drain output, which requires an external pull-up resistor to VCC. The interrupt output is active-low, meaning it is low when an interrupt is generated.
The reset pin (RST) on the PCAL6416AHF is an active-low input that resets the device when pulled low. It is recommended to connect the RST pin to VCC through a pull-up resistor to ensure proper operation.