The maximum power dissipation of the OPA2364AID is 670mW, which is calculated based on the maximum junction temperature (TJ) of 150°C and the thermal resistance (θJA) of 125°C/W.
To ensure stability in a unity-gain configuration, add a 10nF to 22nF capacitor in parallel with a 1kΩ to 2kΩ resistor between the output and the inverting input. This helps to reduce the phase margin and prevent oscillations.
Use a star-grounding technique, where the analog and digital grounds are connected at a single point. Keep the input and output traces short and away from noise sources. Use a ground plane to reduce electromagnetic interference (EMI).
The OPA2364AID is specified to operate from -40°C to 125°C. However, the device's performance may degrade at higher temperatures. Ensure that the device is properly heat-sinked and that the maximum junction temperature (TJ) is not exceeded.
Use shielding, filtering, and grounding techniques to reduce noise and EMI. Add bypass capacitors to the power supply lines, and use a common-mode choke or ferrite bead to filter out high-frequency noise.