The maximum capacitance load for the MTC3528S15 is 0.1uF. Exceeding this value may affect the stability of the output voltage.
The MTC3528S15 is rated for operation up to 80°C ambient temperature. However, derating is required for temperatures above 60°C. Consult the datasheet for derating curves.
The MTC3528S15 meets various safety certifications, including UL, EN, and IEC. However, specific certifications may require additional testing or documentation. Consult with XP Power or a certified test house for customized certification.
A recommended PCB layout for the MTC3528S15 is available in the datasheet or application notes. Key considerations include keeping the input and output capacitors close to the module, and using a solid ground plane for heat dissipation.
Yes, multiple MTC3528S15 modules can be paralleled for higher power. However, it's essential to ensure proper synchronization and current sharing between modules. Consult XP Power's application notes for guidance on paralleling modules.