The maximum operating temperature range for the MPC5517GAVMG80 is -40°C to 125°C, as specified in the datasheet. However, it's essential to note that the device's performance and reliability may degrade at extreme temperatures.
The clock settings for the MPC5517GAVMG80 can be configured using the Clock Management Unit (CMU) registers. The CMU allows you to select the clock source, configure the clock frequency, and enable/disable clock outputs. Refer to the device's reference manual for detailed information on clock configuration.
The maximum current consumption of the MPC5517GAVMG80 depends on the operating frequency, voltage, and peripheral usage. According to the datasheet, the maximum current consumption is approximately 350 mA at 1.2V and 120 MHz. However, this value can vary depending on the specific application and usage.
The MPC5517GAVMG80 has several low-power modes, including Stop, Wait, and Doze modes. These modes can be enabled using the Power Management Controller (PMC) registers. You can also use the device's sleep-on-exit feature to automatically enter a low-power mode when the CPU is idle.
The maximum memory bandwidth of the MPC5517GAVMG80 is 2.4 GB/s, which is achieved using the device's 64-bit data bus and 120 MHz clock frequency.