A 2-layer or 4-layer PCB with a solid ground plane and thermal vias is recommended. Place the device near a thermal pad or a heat sink to improve heat dissipation.
Monitor the input voltage, output voltage, and output current to ensure they are within the specified ranges. Use a voltage regulator or a voltage divider to regulate the input voltage if necessary.
A low-ESR ceramic capacitor (e.g., X5R or X7R) with a value of 4.7uF to 10uF is recommended for input decoupling. Place the capacitor as close to the device as possible.
Use the formula: ΔVout = (Iout * Rload) / (fsw * Cout), where ΔVout is the output voltage ripple, Iout is the output current, Rload is the load resistance, fsw is the switching frequency, and Cout is the output capacitance.
A low-ESR ceramic capacitor (e.g., X5R or X7R) with a value of 10uF to 22uF is recommended for output filtering. Place the capacitor as close to the device as possible.