The maximum operating temperature range for the MINT1180A4875K01 is -40°C to 85°C, with a derating of 2.5% per °C above 60°C.
Yes, the MINT1180A4875K01 is designed to operate in humid environments, with a relative humidity of up to 95% non-condensing.
The recommended input fuse rating for the MINT1180A4875K01 is 2A, slow-blow type.
No, it is not recommended to parallel multiple MINT1180A4875K01 units, as this can lead to instability and reduced reliability. Instead, consider using a higher-power version of the module or a different power supply solution.
The typical efficiency of the MINT1180A4875K01 is around 87% at full load, with a minimum efficiency of 85% over the entire input voltage range.