The maximum operating frequency of the MC908GZ32CFAE is 32 MHz, but it can be overclocked to 40 MHz with some limitations.
The internal clock source of the MC908GZ32CFAE can be configured using the CLKSEL register. The clock source can be set to either the internal oscillator, external oscillator, or the PLL clock.
The maximum amount of current that the MC908GZ32CFAE can source or sink on its I/O pins is 25 mA per pin, with a total current limit of 100 mA for all I/O pins combined.
The MC908GZ32CFAE has a built-in watchdog timer that can be enabled and configured using the COPCTL register. The watchdog timer can be set to timeout after a specified period of inactivity, and can be reset using the COPRST register.
The minimum voltage required for the MC908GZ32CFAE to operate is 2.7V, but it is recommended to operate the device at a voltage of 3.0V or higher for optimal performance.