The maximum operating temperature range for the MC908AZ32ACFUE is -40°C to 105°C.
The internal clock source for the MC908AZ32ACFUE can be configured using the Clock Generator Module (CGM) registers. The CGM provides a flexible clock generation system that allows the user to select from various clock sources, including the internal oscillator, external oscillator, and PLL.
The maximum frequency of the internal oscillator on the MC908AZ32ACFUE is 4 MHz.
The ADC on the MC908AZ32ACFUE is a 10-bit successive approximation ADC. To use the ADC, the user must configure the ADC module, select the analog input channel, and start the conversion process. The ADC result can then be read from the ADC result register.
The maximum current consumption of the MC908AZ32ACFUE is 15 mA at 2.7V and 4 MHz.