The maximum operating temperature range for the MBRA140TR is -55°C to 150°C.
Yes, the MBRA140TR is designed for high-frequency switching applications up to 100 kHz.
The typical reverse recovery time (trr) for the MBRA140TR is around 35 ns.
Yes, the MBRA140TR can be used in parallel to increase current handling, but it's essential to ensure that the devices are properly matched and thermally coupled to prevent uneven current sharing.
The recommended storage temperature range for the MBRA140TR is -40°C to 125°C.