The M48Z512A-70PM1 can operate from -40°C to +85°C, making it suitable for industrial and automotive applications.
The POR and VS functions are internally connected and require no external components. The device will automatically reset and hold in reset mode until the power supply voltage reaches the minimum operating voltage (VCC(min)).
The VCCP pin is the power supply pin for the programming voltage. It should be connected to a 5V power supply, and a 10kΩ resistor should be connected between VCCP and VCC to prevent back-powering.
The M48Z512A-70PM1 has a built-in battery switch-over circuit that automatically switches to the internal battery when the external power supply fails. This ensures data retention during power-down or battery removal.
It is recommended to use a solid ground plane and to route the power and ground pins as close together as possible to minimize noise and ensure reliable operation.